Circutor CVMk2 Series Manuale Utente Pagina 71

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 152
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 70
71
CVM
k
2
CONFIGURATION
4.7.6.4. Static outputs conguration
The outputs of the expansion card are congurating in that screen. The transistor are called
OUT 01, OUT 02, OUT 03 and OUT 04.
On this screen you congure alarms equations that are applied to select the outputs of the
device. You can set up equations with functions AND (*) and / or OR (+) in one or more of the
16 pre-congured alarms (see section 4.7.6.3 Alarm conguration), to activate each of the 4
output transistor of the team.
To modify the conguration parameters of the card, you must press the EDIT (F4). Select the
output you want to congure and press SET to enter editing.
1
A. OUTPUTS T. OUTPUTS
2345678 9 1 2345678 9
1- COMMON
2- Analogic output 1
3- COMMON
4-
Analogic output 2
5- COMMON
6-
Analogic output 3
7- COMMON
8-
Analogic output 4
9- No used
1- COMMON
2- COMMON
3-
4-
5-
6-
7-
8-
9- Transistor ouput 4
COMMON
COMMON
COMMON
Transistor ouput 1
Transistor ouput 2
Transistor ouput 3
4.7.6.5. Outputs wiring
The layout of the outputs of the expansion card is as follows
Vedere la pagina 70
1 2 ... 66 67 68 69 70 71 72 73 74 75 76 ... 151 152

Commenti su questo manuale

Nessun commento