Circutor MDC-20 Manuale Utente Pagina 27

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 58
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 26
MDC-20
User Manual Page 27 of 58
Fig.7-7 . Configuration of counter / meters
Meters: It is possible to configure the following parameters for each of the eight meters:
Description: Alphanumeric name to identify the meter on the unit screen.
Unit: Alphanumeric type data to identify the meter units.
Factor: Multiplier value of each pulse, (for example kWh/impulse ratio)
Flows: Checking the selector will activate the flow variable. If this selector is not activated, it
will not be possible to view the flow value of the corresponding controller input.
Fig.7-8 . Configuration of flow meters
To configure the flow meters the following fields must be defined:
Description: Alphanumeric type data which allows you to enter a brief description of the
flow for better identification.
Unit: Alphanumeric type data which permits a brief description of the units where the
flow is shown to be entered.
Factor: Multiplier value of each input impulse, (for example litres/impulse)
Time (min): Time in minutes for calculating the flow value.
Calculation window (s): Time window, in seconds, that the software uses to calculate
an estimate of the flow, taking into account the value of the unit 's meter.
Digital inputs: To configure digital inputs, a description must be defined for each of them.
Vedere la pagina 26